Omni Group Step Top Wood Stove 57ST-ACC Manuel D’Utilisation

Page de 52
November 28, 2011
7038-159D
Page  11
R
5700 Step Top Wood Stove Series ACC
J.  Burn Rates and Operating Effi ciency
For maximum operating effi ciency 
1.  This appliance has a timer system (ACC) that operates 
the  appliance  at  its  maximum  effi ciency  removing  any 
guess work for the homeowner.  Follow the instructions 
below for each burn rate for the Start-Up Air Control and 
Burn Rate Air Control.  Figure 11.1.
2.  Burn dry, well-seasoned wood.
Burn Rates
1.  Starting a Fire 
• 
Open both controls fully by raising the Burn Rate Air Con-
trol all the way up until it stops and slide the Start-up Air 
Control back until it stops.
  
•  The blower tends to cool the appliance.  Leave the blower 
off until the burn is well established, i.e., 30 minutes.
• 
After  loading  the  appliance  with  wood  and  starting  the 
fi re, set both controls to the desired setting by following 
the burn rate instructions below.
2.  High Burn Rate - Maximum Heat* - 30,000+ BTU/hr
•  Raise the Burn Rate Air Control all the way up until it stops 
(top marker) to a fully open position.  
• 
Slide the Start-Up Air Control all the way back until it stops 
(HI marker) and leave it there. 
•  This  setting  over-rides  the  timer  system  (ACC)  so  you 
must monitor the fi re closely while in this setting to avoid 
overfi ring your stove.
3.  Medium-High Burn Rate*
 -
 15,000 to 30,000 BTU/hr
• 
Raise  the  Burn  Rate  Air  Control  all  the  way  up  until  it 
stops (top marker) to a fully open position.  
Blower may 
remain on.
• 
Slide  the  Start-Up  Air  Control  all  the  way  back  until  it 
stops (HI marker) and then pull forward until it stops.
•  This activates the timer system (ACC).
4.  Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
•  Raise the Burn Rate Air Control up to the bottom of the 
middle  marker  and  stop.    Leave  the  blower  off  until  the 
burn is well established, i.e., 30 minutes.
•  Slide  the  Start-Up Air  Control    all  the  way  back  until  it 
stops (HI marker) and then pull forward until it stops.  
•  This activates the timer system (ACC).
Figure 11.1  
After activating the timer (ACC), if the control is placed 
within the rear air section on the label it will allow rear air 
to enter the fi rebox.  This will not interfere with the timer 
gradually closing the front air channel in 25 minutes.  If 
control is set on “HI” it over-rides the timer (ACC).
*NOTE:  These are approximate settings, and will vary with 
type  of  wood  or  chimney  draft.  Due  to  altitude  and  other 
environmental circumstances, this operational information is 
a guideline only.  
WARNING! Risk of Fire!
When set on High Burn Rate and over-riding the Automatic 
Combustion Control system an overfi re situation can occur 
and may result in a chimney fi re.
Overfi ring will void the stove warranty
.
START-UP
REAR AIR
HI
Closed
Wide
Open
“HI” setting
over-rides
Timer
High (Open)
Low (Closed)
Start-Up Air 
Control
Burn Rate 
Air Control
Front Air Channel 
Operated by Timer
Rear Air Channel
Operates independently 
from Timer
Timer
Timer  Manual 
Shut-off
HIGH
LOW
Shown with Side 
Shield Removed
5.  Low Burn Rate* - Below 10,000 BTU/hr
•  Leave  the  Burn  Rate Air  Control  at  the  bottom  marker.  
Leave the blower off until the burn is well established, i.e., 
30 minutes.
• 
Slide  the  Start-Up  Air  Control  all  the  way  back  until  it 
stops (HI marker) and then pull forward until it stops.