Castile & Santa Fe CE Pellet Stove 
7068-112
Miniumum Vertical Vent for Three Elbows
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
0
1
2
3
4
Length of Horizontal Sections (M)
M
in
im
um
 V
er
tic
al R
is
(M)
Miniumum Vertical Vent for Two Elbows
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0
1
2
3
4
5
6
Length of Horizontal Sections (M)
M
in
im
um
 V
er
tic
al R
is
e (
M
)
C. Pellet Venting Charts
Figure 26.1
Fire Risk.
•  Only  LISTED  venting  components  may  be
used.
•  NO OTHER vent components may be used.
Substitute or damaged vent components may
impair safe operation.
WARNING
The maximum horizontal venting allowed with no vertical vent-
ing attached is 219mm including one 90° elbow or two 45°
elbows. This is our recommended horizontal venting instal-
lation.    Addition  of  any  horizontal  venting  beyond  1219mm
Hearth & Home Technologies strong recommends a minimum
of 1524mm of additional vertical vent. Horizontal sections of
vent pipe should have a 6.35mm rise per foot.
Hearth  &  Home  Technologies  recommends  any  installation
requiring  more  than  two  90°  elbows,  or  more  than  4.5m  of
venting to use 102mm vent.
NOTICE: 
These are guidelines for successful venting of your pellet appliance. The more vertical rise you can obtain in your system,
the better it will perform. Horizontal vent runs can accumulate ash and will need to be cleaned more often. Try to keep them as short
as possible.
45° elbow is equivalent to 30.48cm of straight pipe
90° elbow is equivalent to 91.44cm of straight pipe
Miniumum Vertical Vent for One Elbow
0.00
1.00
2.00
3.00
4.00
5.00
6.00
0
1
2
3
4
5
6
Horizontal Run (M)
M
in
im
um
 V
er
tic
al R
is
(M)
Figure 26.2
Figure 26.3
ONE 90º ELBOW
Total
Horizontal
Minimum
Vertical
Vent
Diameter
4
0
3
5
5
3
6
6
3
7
7
3
8
8
4
9
9
4
10
10
4
11
11
4
12
12
4
13
13
4
14
14
4
15
15
4
16
16
4
17
17
4
18
18
4
19
19
4
TWO 90º ELBOWS
Total
Minimum
Vent
Horizontal Vertical
Diameter
2
5
3
3
6
3
4
7
3
5
8
3
6
9
3
7
10
4
8
11
4
9
12
4
10
13
4
11
14
4
12
15
4
13
16
4
14
17
4
15
18
4
THREE 90º ELBOWS
Total
Minimum
Vent
Horizontal  Vertical Diameter
2
11
4
3
12
4
4
13
4
5
14
4
6
15
4
7
16
4
8
17
4
9
18
4
10
19
4
11
20
4