EIA-366 Dialer Operation
The telephone number can have up to 40 digits, including 
special characters. If more than 40 digits are received, the dialer 
turns on ACR and waits for CRQ to drop. The characters are 
defined as follows:
* and #:
These are used for clarity only.
EON digit:
The EON digit is used when the line is
configured as a nailed-up line. The EON
digit signals that the end of the number has
been received. When it is received, DSC is
turned on. When configured for nail-up
line, it is not necessary to wait for the
connection before turning on DSC.
Other characters defined by EIA-366 are not supported by the 
UTA220 dialer. Unsupported characters in a dial string are 
ignored by the dialer.
Digit Present (DPR)
DPR is sent by the DTE to indicate to the dialer that the code 
on the Digit Signal Circuits can be read. Circuit DPR must not 
be turned on before Present Next Digit (PND) comes on. When 
DPR is on, it must remain on until PND goes off. When DPR 
is off, it must be held off until PND comes on again. If DPR is 
not turned on within five seconds after PND is turned on, the 
dialer assumes it has received the last digit and dials any digits 
that have been received. If no digits have been received, the 
dialer turns on Abandon Call and Retry (ACR) and waits for 
Call Request (CRQ) to drop.
Present Next Digit (PND)
PND is turned on by the dialer to indicate that it is ready to 
accept the next digit on the digit signal circuits NB1, NB2, NB4, 
and NB8. Off indicates that the DTE should turn off DPR and 
set the states of NB1, NB2, NB4, and NB8 for the next digit.
9
1
0
0
1
*
1
0
1
0
#
1
0
1
1
<  (EON)
1
1
0
0
Table 7-2: Dial Digit Character Set (Continued)
Digit
NB8
NB4
NB2
NB1