Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
7-4
UTA220/UTA220k
EIA-366 Dialer Operation
Abandon Call and Retry (ACR)
ACR is supplied by the dialer to indicate that the call cannot 
be successfully established. The on condition instructs the 
DTE to abandon the call by dropping the call later. ACR 
remains on until CRQ is turned off.
EXAMPLE DIAL SEQUENCE
The following is an example of the sequence of events that 
occur when a call is initiated using the EIA-366A dialer port.
• Data Line Occupied (DLO) must be off for the dial sequence 
to begin.
• The DTE turns on Call Request (CRQ) to initiate dialing.
• When CRQ is turned on, the dialer port turns on DLO to 
indicate that the data port is now in use. The dialer turns on 
Present Next Digit (PND) to request a dial digit from the 
DTE.
• The DTE sets the digit signal circuit bits (NB1, NB2, NB4, 
and NB8) to the correct value for the first dial digit, then turns 
on Digit Present (DPR).
• When DPR turns on, the dialer reads the digit and responds 
with another PND.
• The PND/DPR sequence continues until either EON is 
received or five seconds expires without receiving another 
digit (DPR is not turned on to present another digit).
• When all the digits are received, the dialer initiates the call 
on the data port to which the dialer is dedicated.
• When the call is connected, Distant Station Connected (DSC) 
is turned on by the dialer port. If the call cannot complete 
successfully, Abandon Call and Retry (ACR) is turned on 
until CRQ is turned off.
• The call can be terminated before the call is connected by 
turning CRQ off.
• Once the call is completed, the call can be terminated by 
normal disconnect methods such as disconnect by the switch, 
the front panel, or DTR disconnect.