Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
12-20
UTA220/UTA220k
D-Channel X.25
Parameter 2: Echo
This parameter establishes whether or not characters 
transmitted from the local DTE device to the PAD is echoed 
back to the local DTE device by the PAD. For example, if echo 
is enabled and the letter   P   is typed, the PAD transmits the 
letter   P back to the terminal.
 default
Parameter 3: Selection of Data Forwarding Characters
Characters received from the local DTE device are stored by 
the PAD until the data forwarding character is received, or 
some other data forwarding condition has occurred. Parameter 
3 designates the character or set of characters used to initiate 
the forwarding of the data stored by the PAD. Before the data 
forwarding character is transmitted to the PAD, the data stored 
by the PAD can be edited if parameter 15 is enabled.
Other conditions that cause the PAD to automatically forward 
the data stored by the PAD are as follows:
• If editing is disabled (parameter 15 = 0) and the PAD receives 
enough data to fill a packet, one full packet is forwarded.
• If editing is enabled (parameter 15 = 1) and the PAD receives 
enough data to fill the PAD editing buffer, the PAD forwards 
one full packet.
• If the maximum assembly timer expires before any other data 
forwarding conditions occur, the data currently stored by the 
PAD is forwarded. The maximum assembly timer is started 
on receipt of the first character being packeted by the PAD 
from the DTE and expires after 15 minutes.
• If editing is disabled (parameter 15 = 0) and the idle timer 
delay expires (as set by parameter 4), the data currently stored 
by the PAD is forwarded. 
• If the PAD receives a break and the action to be performed 
upon receipt of a break is nothing (parameter 7 = 0), the data 
currently stored by the PAD is forwarded.
• If the PAD receives the first character of a PAD command 
signal after escaping from the data transfer mode, the data 
currently stored by the PAD is forwarded.
• If the PAD receives a set, read, or set and read PAD message 
from the remote DTE, the data currently stored by the PAD 
is forwarded.
Table 12-8: Echo
Value
Description
0
No character echo
1
Character echo enabled (under the restraints or (parameter 20) 
during all modes of the PAD *