Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
12-22
UTA220/UTA220k
D-Channel X.25
Parameter 5:  Ancillary Device Control
Parameter 5 specifies whether or not flow control of the local 
DTE device (ancillary device) by the PAD can occur, and if so, 
what modes of the PAD the PAD flow control of the local DTE 
are allowed. Flow control of the local DTE device is handled in 
conjunction with S54 (DTE flow control register). The type of 
flow control the PAD transmits to the local DTE device is set 
according to the setting of S54. For example, if S54 is set for 
CTS flow control, the PAD will flow control the local DTE 
device by turning off the CTS pin when the PAD can no longer 
accept any characters from the local DTE. When the PAD can 
resume accepting characters from the local DTE, the PAD turns 
the CTS pin on. If all the DTE flow control options are disabled 
(default), the PAD will transmit XON (Ctrl Q) and XOFF 
(Ctrl S) to the local DTE for flow control.
*default
Note: The function of parameter 5 differs from the 1984 CCITT 
X.3 Specification. The specification indicates that only XON 
and XOFF can be transmitted to the DTE for the purpose of 
flow control. The TA does not restrict the type of flow control 
used on the local DTE. The setting of the AT command indicates 
the type of flow control sent to the DTE. Thus, if the DTE device 
only recognizes CTS flow control, the PAD can still flow control 
the DTE.
Parameter 6: Control of PAD Service Signals
Parameter 6 specifies whether the PAD prompt or PAD service 
signals are transmitted to the local DTE device by the PAD, and 
the format of those service signals. The PAD service signals are 
character messages transmitted to the local DTE device by the 
PAD in response to PAD commands issued by the local DTE 
or to inform the user of a packet or network action (i.e., call reset 
etc.). The PAD prompt is the character *. It is transmitted by 
the PAD to the local DTE device when the PAD is in PAD 
command mode to prompt the user to enter a PAD command.
For non-interactive applications, the service signal transmission 
to the local DTE may be disabled as the transmission service 
signals can appear to be part of the received data.
Table 12-11: Ancillary Device Control
Value
Description
0
No PAD flow control
1
PAD data transfer flow control 
2
PAD data transfer and PAD command mode flow control  *