Frequency range
 
PentaScanner+
: 1.0 to 100 MHz
 
PentaScanner
/
PentaScanner
 
Cable Admin
: 1.0 to 100 MHz
 
Sweep mode:   Swept 1- 100 MHz using 1 MHz step or fixed points (1.0, 2.0, 4.0,5,0, 8.0,
10, 16.0, 20, 25, 31.25, 62.5, and 100 MHz)
 
Dynamic Range: 0 - 50 dB
 
Measurement Accuracy:
 
PentaScanner+
: Calculated per TIA TSB-67 error model (see NEXT and Attenuation
Specifications table)
 
PentaScanner
/
PentaScanner
 
Cable Admin
: 1.5 dB
 
Measurement resolution: 0.1 dB
Impedance
 
Range: 
40 to 200 ohms
 
Accuracy: 
± 5 ohms
 
Resolution: 2 
ohms
Loop Resistance
 
Range: 
0 to 10000 ohms
 
Accuracy: 
± 0.3 ohms @ 0 to 15 ohms
 
± 2%  @ 15 to 109 ohms (
PentaScanner+
)
 
± 2%  @ 15 to 200 ohms (
PentaScanner
/
PentaScanner
 
Cable Admin
± 5%  @ 109 to 5000 ohms (
PentaScanner+
)
 
± 5%  @ 200 to 5000 ohms (
PentaScanner
/
PentaScanner
 
Cable 
Admin
± 10%  @ 5000 to 10000 ohms 
 
Resolution:
0.1 ohms 
0 to 200 ohms
1.0 ohms 
200 to 9.999K ohms
Capacitance
 
Range: 
0 to 100,000 pF
 
Accuracy: 
± 20 pF
0 to 200 pF 
 
± 10%
200 to 100,000 pF
 
Resolution: 
5 pF
20 to 1000 pF 
50 pF
1000 to 100,000 pF
Impulse Noise
 
Detects the occurrence of narrow impulse type events exceeding an adjustable threshold of
 
± 0.262, 0.524, 1.0, 2.0 or 2.5 volts. Instantly displays up to 200 impulse noise events per
second. Graphically logs and displays impulse events for up to 25 hours. Termination
impedance: 200 ohms.
Peak to Peak Noise
 
Measures the peak to peak voltage of steady state noise signals.
 
Range: 0 to 3,000 mVpp into 100 ohms.
 
Bandwidth: 3dB from 40 kHz to 30 MHz