Microtest TSB-67 - 568A Annex E Manuel D’Utilisation

Page de 61
Page 55
High Voltage Input/Protection
 
The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less than 80 mA) or 24 VAC power used to power many telephone
keysets.
2-Way Injector+/2-Way Injector
Environmental, Physical Characteristics, User Interface, Measurement Port
Refer to specifications for 
PentaScanner+
/
PentaScanner
/
PentaScanner
 
Cable Admin
LED Displays
 
Pass Indicator (GREEN) for test result
 
Fail Indicator (RED) for test result
 
Status Indicator (GREEN) for 2-Way Injector status
 
Charging Indicator (RED) for battery status
 
Hazard Indicator (RED) for high voltage input protection warning
Audible Feedback
 
Programmable tone generation through a piezo-electric transducer to signal test is complete or
overvoltage conditions
Rechargeable Battery
 
Removable, rechargeable Nickel Cadmium (Ni-Cd)
 
Capacity:
1200 mAh
 
Battery Life:
 8+ hours daily operation
 
Charging Time: 
14 hours (via AC Adapter) 
2-3 hours (via Battery Charger)
High Voltage Input/Protection
 
The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less that 80 mA) or 24 VAC power used to power many telephone
keysets.
FLASH Memory
 
128K FLASH memory is provided to allow for software updates in the field
Power Control
 
AC Adapter or Battery
 
Auto-shutoff when operating on battery
 
Power on under Scanner control
Injector End Termination to Support Scanner Measurements
 
OPEN (during Impedance, Capacitance, and Length measurements and during
Communication)
 
SHORT (during Loop Resistance measurements)
 
100 Ohm Termination (during NEXT measurements)
 
Swept signal injections during Autotest