Lucent Technologies Window SLV 9124 Manuel D’Utilisation

Page de 271
SNMP MIBs and Traps, and RMON Alarm Defaults
 B-17
9124-A2-LB20-00
March 2000
Frame Relay Link Alarm Defaults
These alarms apply to the FrameSaver unit’s frame relay link interfaces. They are
created during RMON initialization.
Table B-10.
Frame Relay Link Alarm Defaults (1 of 2)
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
Invalid Frames
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxIlFrames
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.18.I
900 secs
(15 mins)
Rising
1
1
Short Frames
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxShort
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.6.I
900 secs
(15 mins)
Rising
1
1
Long Frames
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxLong
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.7.I
900 secs
(15 mins)
Rising
1
1
Rx Discards
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkRxDiscards
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.15.I
900 secs
(15 mins)
Rising
1
1
Tx Discards
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkTxDiscards
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.14.I
900 secs
(15 mins)
Rising
1
1
Rx Total Errors
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtLinkTotRxErrs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.7.1.20.I
900 secs
(15 mins)
Rising
1
1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
2
in the OID = Interface ID of the frame relay link.