Lucent Technologies Window SLV 9124 Manuel D’Utilisation

Page de 271
SNMP MIBs and Traps, and RMON Alarm Defaults
 B-19
9124-A2-LB20-00
March 2000
DLCI Alarm Defaults – Paradyne Area
These alarms apply to all DLCIs on the network interface and can be created
during RMON initialization or when a DLCI is created. They are put into the
Paradyne alarm area.
Table B-11.
DLCI Alarm Defaults – Paradyne Area
Item
Sample
Type
1
MIB/Tag/OID
2
Interval
Event
Type
Rising
Threshold
Default
Falling
Threshold
Default
DLCI Inactive
Seconds
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciStsInactive-
Secs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.2.I.D
900 secs
(15 mins)
Rising
1
1
Missing Latency
Responses
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciMissedSLVs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.23.I.D
900 secs
(15 mins)
Rising
5
5
Rx FECNs
D
MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitReceivedFECNs
OID: .1.3.6.1.2.1.10.32.2.1.
4.I.D
60 secs
(1 min)
Rising
1
1
Rx BECNs
D
MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitReceivedBECNs
OID: .1.3.6.1.2.1.10.32.2.1.
5.I.D
60 secs
(1 min)
Rising
1
1
Congested Seconds
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciSts-
CongestedSecs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.6.I.D
60 secs
(1 min)
Rising
5
5
Frames Dropped by
Network
D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciNetDropFr
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.20.I.D
60 secs
(1 min)
Rising
1
1
1
D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.
2
in the OID = Interface ID of the frame relay link.
D = DLCI number.