Configuration
 3-15
9124-A2-LB20-00
March 2000
Setting Up So the Router Can Receive RIP
"
Procedure
1. Configure the router to receive RIP.
For example, if using a Cisco router, configure 
config-t
router RIP
,
int serialx
IP RIP Receive version 1
, then 
ctl-z WR
.
2. Create a Standard DLCI for the user data port.
Configuration
Data Ports
DLCI Records
3. Create a Management PVC using the user data port DLCI just configured.
Configuration
Management and Communication
Management PVCs
4. Set Primary Link RIP to Standard_Out, and Save the configuration.
Setting Up Service Provider Connectivity at the Central Site
When management needs to be set up between a service provider’s customer
and its network operations center (NOC), a non-multiplexed DLCI must be
configured to carry management data between the customer’s central site and
the NOC console. This requires that a frame relay discovered DLCI needs to be
modified. This is because all auto-configured network DLCIs are configured as
multiplexed DLCIs.
"
Procedure
To set up NOC management:
1. Select DLCI Records on the network interface.
Configuration
Network
DLCI Records
2. Select Modify. The 
Modify DLCI Record for DLCI Number
 prompt
appears.
3. Select the DLCI that will be used by pressing the spacebar until the correct
DLCI number appears, then select it.
4. Change the DLCI Type from Multiplexed to Standard.
The
 DLCI in connections. Update DLCI usage as follows:
prompt appears.