Linksys BUSINESS SPA932 Manuel D’Utilisation

Page de 196
Linksys SPA9x2 Phone Administration Guide
65
Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones
Setting Regional Parameters
  • Example 1: Dial Tone 
  • 350@-19,440@-19;10(*/0/1+2) 
  • Number of Frequencies = 2 
  • Frequency 1 = 350 Hz at –19 dBm 
  • Frequency 2 = 440 Hz at –19 dBm 
  • Number of Cadence Sections = 1 
  • Cadence Section 1: Section Length = 10 s 
  • Number of Segments = 1 
  • Segment 1: On=forever, with Frequencies 1 and 2 
  • Total Tone Length = 10s 
  • Example 2: Stutter Tone 
  • 350@-19,440@-19;2(.1/.1/1+2);10(*/0/1+2) 
  • Number of Frequencies = 2 
  • Frequency 1 = 350 Hz at –19 dBm 
  • Frequency 2 = 440 Hz at –19 dBm 
  • Number of Cadence Sections = 2 
  • Cadence Section 1: Section Length = 2s 
  • Number of Segments = 1 
  • Segment 1: On=0.1s, Off=0.1s with Frequencies 1 
and 2 
  • Cadence Section 2: Section Length = 10s 
  • Number of Segments = 1 
  • Segment 1: On=forever, with Frequencies 1 and 2 
  • Total Tone Length = 12s