IntraServer Technology ITIpci 5100G/GF Manuel D’Utilisation

Page de 56
 
LSI Logic Corporation  
                               Page 23 of 56                       
________________________3 
The ITI-5100G/GF Driver Software 
 A network device driver must be installed before the ITI-5100G/GF adapter 
can be used with your systems.  This chapter describes how to preform the 
following tasks: 
 Install the driver software in the Solaris environment 
 Configure the host files 
 Configure driver parameters using the ndd utility 
Installing the Driver Software 
Note: The ITI-5100G/GF adapter must be physically installed in your 
server prior to installing the driver software.  See “Installing the ITI-
5100G-GF Hardware,” for details. 
To install the adapter software for Solaris, perform the following procedure: 
1. 
Become superuser (root). 
2. 
Note the revision level of the Software Distribution Media included 
with your IntraServer Technology adapter. 
The revision level is stamped on the Software Distribution Media 
label and is used in the commands below. 
Place the Software Distribution Media into the CD-ROM drive. 
Mount the CD-ROM on a local directory. 
 If the Volume manager (vold) is running on your machine, when the 
ITI-5100G/GF CD-ROM is loaded into the drive, it is mounted 
automatically under  /cdrom/cdrom0
#volcheck
Access the package directory by entering the following: 
# cd /cdrom/cdrom0