Hydro Smart 115 Manuel De Montage

Page de 44
Installation 
21
Page
 
Follow the electrical code requirements of the local authority having 
jurisdiction. In the absence of such requirements, follow the latest edition of 
the National Electrical Code ANSI/NFPA 70 in the U.S. or the latest edition of 
CSA C22.1 Canadian Electrical Code, Part 1, in Canada. 
When servicing or replacing parts within the water heater, label all wires 
prior to disconnection to facilitate an easy and error‐free reconnection.  
Wiring errors can cause improper and dangerous operation. Verify proper 
operation after servicing.
 
ELECTRICAL CONNECTIONS 
 
 
 
  
 
 
 
 
 
 
 
 
 
The indoor model comes with a power plug instead of a junction box. The following procedure is for 
outdoor models only. 
 
1. 
The water heater must be electrically grounded. Do not attach the ground wire to either the gas or 
the water piping.
 
2. 
The water heater requires 120 VAC / 60 Hz electrical power supply that is properly grounded. 
  A proper disconnect (i.e. on/off switch, power plug, etc.) controlling the main power to the 
water heater must be provided for service reasons.  (Must comply with local codes). 
  Connect the power supply to the water heater exactly as shown in the wiring diagram;  
 
3. 
A green screw is provided in the junction box to ground the connection.  
4. 
Can be hardwired or wired to a plug‐in.  
5. 
The use of a surge protector is recommended in order to protect the unit from power surges.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAUTION 
WARNING 
View of electrical connections of water heater
Connect
Power supply 
120 VAC / 60 Hz 
Ground
Green screw 
Outdoor model only 
Bottom view  
of water heater 
Indoor model only