HP 288048 Manuel D’Utilisation

Page de 30
Installation
311053C
5
Installation
Ventilate Spray Booth
Configure Gun and Manifold
(Order manifold separately. See Accessories, page 
26.)
Manifolds 241161 and 241162
The gun is supplied with an internal fluid plug (4). See 
F
. 1. To use the gun in a circulating system, remove 
the internal plug. In a non-circulating system, leave the 
plug in place to minimize flush time.
Circulating System
1.
Apply anti-seize lubricant 222955 to the threads and 
mating faces of the manifold (101) and the elbows 
(107), supplied unassembled. 
2.
Install the elbows (107) in both fluid ports of the 
manifold (101). 
3.
Connect the fluid supply line to one elbow and the 
fluid return line to the other. The manifold fluid ports 
are reversible.
Non-circulating System:
1.
Apply anti-seize lubricant 222955 to the threads and 
mating faces of manifold (101), plug (109), and 
elbow (107), supplied unassembled. 
2.
Install an elbow (107) in one fluid port of the mani-
fold (101), and a plug (109) in the other port. 
3.
Install the internal plug (4) in the gun fluid port on 
the same side as the manifold plug. 
4.
Connect the fluid supply line to the manifold elbow 
(107). See F
5.
Install the gun on the manifold, using the four 
screws (14). Start the threads of all four screws, and 
tighten the front two screws first, and then tighten 
the back two screws to 65 in-lb (7.3 N•m).
Check and follow all National, State, and Local 
codes regarding air exhaust velocity requirements.
Check and follow all local safety and fire codes.
F
IG
. 1: Non-Circulating Setup (Cutaway View)
TI8587b
1
Remove when used in circulating systems.
1
Replace with an elbow (107) when used in circulating 
systems.
2
2
101
107
109
4
6
5