Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
21020285 D
User’s Guide
 Chapter 7   Board-control Commands
Page 7 - 18 
Unit Options (08H) 
Unit Options 
(08H)
The Unit Options command allows you to individually tailor how the RF3880 
adapter operates, in either initiator or target mode, with each SCSI device on 
the bus. 
Usually these options need be set only once, at power-up, to create the proper 
operating environment. Each unit you need to set-up requires a separate Unit 
Options command.
Command
Format
The Parameter Block for the Unit Options command looks like this:
Description of
Fields
Each of the fields of the Parameter Block are described below:
Command Identifier
This field is used if you are issuing the Unit Options command through the 
structure of a Command List. It is used to identify the Status block returned 
from the command. It should be a unique value.
Adapter ID
This command performs no action on a specific SCSI device. It is a Board-
control command and so this field must be FFH.
Unit SCSI ID
This field must contain a number from 0 - FH representing a SCSI device on 
the bus. Do not use the RF3880 adapter SCSI ID you assign with the General 
Options command.
Address 
Offset
Byte Memory Address
Offset + 0
Offset + 1
Offset + 2
Offset + 3
00H
Command Identifier
04H
Disconnect Time-out
Unit SCSI ID
Adapter ID = FFH
08H
Select Time-out
Retry Control
Retry Limit
0CH
Reserved
Reserved
Sense Count
Unit Flags
10H
Command = 08H
Reserved
14H
Sense Byte #
Sense Byte #
Sense Byte #
Sense Byte #
18H
Sense Byte #
Sense Byte #
Sense Byte #
Sense Byte #
Table 74: Unit Options Command Parameter Block