Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
21020285 D
User’s Guide
 Chapter 7   Board-control Commands
Page 7 - 20 
Unit Options (08H) 
RCE Retry Command Errors
 - Allows you to select whether the adapter 
will respond to a device error with a retry of the failed command.
 Do not retry for device errors.
 Retry commands that error from the device.
RBE Retry Bus (SCSI) Errors
 - Enables retries in the event that a command 
fails.
 Do not perform Bus Error retries.
 Perform Bus Error retries.
Select Time-out
According to SCSI specifications, a target must respond to initiator selection 
by asserting the BSY signal in response to SEL, with its ID on the bus. With 
this field you can select the amount of time that the RF3880 adapter will wait 
for response before timing out with an error. 
The select time-out period is specified in 1 millisecond increments. The default 
value is 250 (FAH), which selects a period of 250 milliseconds.
The longest time-out period possible is 392 milliseconds, selected with a value 
of 392 (188H) Any larger value placed in this field will still select 392 
milliseconds. 
A value of 0 will select the shortest time-out period possible, which is about 1 
millisecond.
Unit Flags
The Unit Flags field of the Unit Options Parameter Block is where you can 
define command operation for the unit. With bit settings you can address the 
issues of: synchronous data transfer, tagged commands, and use of the ATN 
signal.
Note
If you set the TAG flag 
(explained below) the 
adapter will ignore the 
UNQ bit. Setting the 
TAG bit implies that you 
are using a SCSI-2 or 
SCSI-3 device. The 
UNQ bit is intended for 
SCSI-1 devices.
UNQ Untagged Queuing
 - The SCSI-1 specification allows issue of 
multiple, simultaneous, commands to a target that has multiple LUN’s, one 
command per LUN. This bit allows you to select whether the RF3880 will 
queue commands to a target with multiple LUN’s.
 Send one command at a time to this target.
 Queue commands to this target; it has multiple LUN’s.
SYN Synchronous Negotiation
 - Either the initiator or the target may 
introduce negotiation for synchronous operation. How you set this bit 
determines whether the RF3880 adapter will attempt to negotiate with the 
device. (Even if you do not set this bit to allow negotiation, if the other device 
begins negotiation, the adapter will respond.)
 Do not initiate negotiation for synchronous data transfer.
 Negotiate for synchronous data transfer.
BITS
7
6
5
4
3
2
1
0
0
TAG
0
0
WID
IAT
SYN
UNQ
Table 76: Unit Flags