Extended Board Statistics (16H)
 Page 7 - 43
Extended
Statistics Data
Structure
The Extended Statistics Data Structure returned from an Extended Board 
Statistics command will have this format:
Description of
Fields
The Extended Statistics Data Structure returned from the Extended Board 
Statistics command contains these fields:
Total Commands Issued
This field reports the number of commands, SCSI Pass-through and Board-
control, that have been processed by the adapter since power-up, reset, or the 
CLR bit option was used.
Number of SCSI Bad Status Conditions
This field reports the number of times a status other than Good was reported 
by all SCSI devices.
Number of SCSI Parity Errors
This field reports the total number of SCSI Parity Errors that have occurred 
since power-up, reset, or the CLR bit option was used.
Target Mode Selection Count
This field reports the number of times the RF3880 was selected as a target 
device.
Per SCSI Target — Number of Commands
This field is repeated for each of the 16 possible SCSI Target ID’s. It reports 
the number of commands received by that target since power-up, reset, or the 
CLR bit option was used. (The Number of Commands field for the SCSI ID 
that corresponds to the adapter ID will be zero, as will any ID in the table that 
is not presently used by a device.)
Address 
Offset
Byte Memory Address
Offset + 0
Offset + 1
Offset + 2
Offset + 3
General Board 
Information 
Header
00H
Total Commands Issued
04H
Number of SCSI Bad Status Errors
08H
Number of SCSI Parity Errors
0CH
Target Mode Selection Count
10H
Reserved
14H
SCSI Target ID 0: Number of Commands
Per Target 
Information; 
Targets 0 - 15
18H
Queue Full Count
Maximum Queued
1CH
Reserved
.
.
.
.
.
.
C8H
SCSI Target ID 15: Number of Commands
CCH
Queue Full Count
Maximum Queued
D0H
Reserved
Table 102: Extended Board Statistics Data Structure