Ciprico Rimfire 3880 Manuel D’Utilisation

Page de 230
User’s Guide
21020285 D
Chapter 7   Board-control Commands
 
Extended Unit Options (18H)
 Page 7 - 45
Extended Unit 
Options (18H)
This command, in either initiator or target mode, is designed as an enhancement 
to the Unit Options command. The primary difference between the commands 
is the opportunity to select 16 bytes of Sense Data to be returned per unit, instead 
of the eight offered in the Unit Options command.
Another difference is that the Extended Unit Options for the SCSI device are 
built into a Data Structure whose address is simply passed in the command.
Command
Format
The format of the Extended Unit Options command is as follows:
Description of
Fields
Each of the fields of the Parameter Block are described below:
Command Identifier
The Command Identifier field is used to identify the Status Block associated 
with a Parameter Block. It must be a unique value.
Adapter ID
This is a Board-control command. The value in this field must be FFH.
Address Modifier
This is the value to be used by the adapter on the Address Modifier lines when 
reading the Extended Unit Options Data Structure from memory.
VME Memory Address
This is the system memory address at which you have built the Extended Unit 
Options Data Structure.
Command Code
The value for this field will always be 18H to indicate a Extended Unit Options 
command.
The format of the Data Structure to be used for the Extended Unit Options 
command is illustrated on the following pages.
Address 
Offset
Byte Memory Address
Offset  +  0
Offset  +  1
Offset  +  2
Offset  +  3
00H
Command Identifier
04H
Reserved
Addr. Mod.
Adapter ID = FFH
08H
VME Memory Address
0CH
Reserved
10H
Command = 18H
Reserved
14H
Reserved
18H
Reserved
Table 103: Extended Unit Options Parameter Block