Step 2: Jumpers and Termination 
SCSI bus
Termination
Each end of the SCSI bus cable must be terminated to prevent corruption of the 
data and control signals. The RF3880 adapter has terminator packs on the board. 
These are removable in the case that the adapter is not at the end of the SCSI 
cable.
The adapter provides termination power on the SCSI bus cable. This line is 
fused on the board. The fuse is replaceable.
The location of the terminators and removable termination power fuse are 
shown in the following illustrations.
The following figure illustrates the board termination. 
Note
Two types of SCSI bus 
terminators are used on 
the RF3880 mother 
board. The first two in 
each column, closest to 
the SCSI connector, are 
330—ohm SIPs, and the 
others are 150—ohm 
SIPs.
Figure 11 Board Fuse and Terminators
Note
It is very important to 
replace the termination 
fuse with an exact 
equivalent. If you 
replace the termination 
fuse with a value lower 
or higher, you risk 
continued problems or 
damage to the RF3880 
and attached equipment.
Replacement Fuse
In the event that the termination power fuse is blown, replace it with:
Littlefuse P/N 273-002 or equivalent