Axis International Marketing 2130R PTZ Manuel D’Utilisation

Page de 41
AXIS 2130/2130R User’s Manual
Troubleshooting
 
27 
Symptoms, Possible Causes and Remedial Actions
Symptoms
Possible causes
Remedial actions
The AXIS 2130/2130R cannot 
be accessed from a browser.
The IP address is already 
being used by another 
device.
Run the PING utility (as described above) and follow the 
appropriate recommendations. 
The IP address is located on a 
different subnet.
Run the PING utility (as described in PINGing Your IP Address, on 
page 26).
 If you get “no response” or similar, the diagnosis is 
probably correct.
In Windows, check that the IP address for your AXIS 2130/2130R is 
on the same subnet as your workstation. Exactly how this is done 
varies from one version of Windows to another. See Windows’ help 
for more information.
If your AXIS 2130/2130R and your workstation are on different 
subnets, you will not be able to set the IP address. Contact your 
network administrator.
In Windows 95, the ARP 
table was empty when you 
tried to set the IP address. 
In Windows 95, the ARP command cannot be used if you have an 
empty ARP table. If the table is empty, re-install the product 
ensuring that the IP address for your own PC is also used. 
Type 
arp -a
 to view the ARP table. If it is empty, you must ping 
an existing unit on your network before you can download the IP 
address to the AXIS 2130/2130R, using ARP. 
Note: The AXIS IP Installer is an easy-to-use alternative for 
installing the unit.
The IP address has changed.
Check that there is no DHCP server running on the network and 
disable BOOTP in the admin tools (Network>TCP).
Note: The AXIS IP Installer will not work with DHCP.
Other networking problems.
Test the network cable by connecting it to some other network 
device and then PINGing that device from your workstation.
Test the unit’s network interface by connecting a local computer to 
the unit, using a standard Crossover (hub-to-hub) Cable. 
A programming script is 
locking the unit.
Restore the unit to the factory default settings. 
The Power indicator is not 
constantly lit.
Faulty power supply.
Verify that you are using an Axis PS-D power supply.
The Network indicator 
displays red.
Faulty cabling. 
See Other networking problems, above.
Your AXIS 2130/2130R works 
locally, but not externally.
Firewall protection.
Check the Internet firewall with your system administrator.
Default routers required.
Check if you need to configure the default router settings.
The Internet site is too 
heavily loaded.
Use a script running on your web server to relay images from the 
AXIS 2130/2130R to the Internet.