Avital 4103 Manuel D’Utilisation

Page de 52
26
© 2008 Directed Electronics. All rights reserved.
Programming jumpers
Light flash (+)/(-)
This jumper is used to determine the light flash output polarity. In the (+) 
position, the on-board relay is enabled and the unit will output (+)12V 
on the WHITE wire, H1/9. In the (-) position, the on-board relay is dis-
abled. The WHITE wire, H1/9, will supply a 200mA (-) output suitable 
for driving factory parking light relays
Note:
 For parking light circuits that draw 10 amps or more, the internal 
jumper  must  be  switched  to  a  (-)  light  flash  output. 
P/N 8617
  or  a 
standard automotive SPDT relay must be used on the H1/9 light flash 
output harness wire.