Avaya Bogen APS Custom Guide D’Installation Rapide

Page de 75
6 • 2
APS Custom does not accept
a “valid” extension number.
APS Custom database 
not loaded.
APS Custom database 
c o n f i g u red incorre c t l y.
• Using APS Custom PCI, 
connect to the unit and 
download the database. Ve r i f y
the extension in question is 
c o rrectly entered into the 
d a t a b a s e .
APS Custom answers calls
but does not respond to
DTMF key pre s s e s .
PBX not programmed for
DTMF operation. 
DTMF digit duration is too
s h o rt .
Calling extension on the PBX
does not support DTMF dial
t h rough to called extension.
• Check for proper DTMF 
p rogramming on your local 
PBX. 
• Check for minimum DTMF 
duration of 80 milliseconds.
• Verify the standard analog
telephone connected to the 
APS Custom port can hear
the sent DTMF digits. If  
DTMF digits appear to 
be sent c o rre c t l y, call your
Lucent Hotline Support 
N u m b e r.
APS Custom fails 
to enter voice pr o g r a m m i n g
mode. 
Busy signal r e t u rned 
f rom PBX.
S e rvice Port 1 connected
i n c o rre c t l y.
S e rvice Ports 1 and 2 cro s s e d
(e.g., Service Port 1 connected
to service Port 2 telephone line
and vice versa).
PBX Transfer String not 
p roperly programmed in the
APS Custom PCI.
P o rt 1 could be busy with a
c a l l e r.
• Verify Service Port Telephone 
numbers c o rrespond to 
telephone lines connected to 
S e rvice Ports 1 and 2. 
• Check the Transfer String 
f o rmat in the APS Custom 
PCI. Verify the Transfer 
String follows the proper 
f o rmat for t r a n s f e rring a call 
f rom an analog telephone 
extension.  Verify the format 
with your PBX vendor or 
manual. Test the dialing 
sequence manually on 
another analog extension.
P R O B L E M
POSSIBLE CAUSE(S)
S O L U T I O N
APS Custom does not
answer calls.
Red POWER LED is lit. 
G reen IN USE LED blinks 
on and off. 
G reen PROGRAM LED is lit.
APS Custom connected to PCI
for database modifications.
APS Custom in p ro g r a m m i n g
mode to re c o rd names or
a n n o u n c e m e n t s .
APS Custom processing new
database information after a
download from APS Custom
P C I .
The unit is in programming
mode.
• This condition is not a 
problem. The APS Custom
does not answer calls when 
in Programming Mode.  
Programming Mode is 
active when the Green 
PROGRAM LED is lit.  
The APS Custom
should begin answering 
calls when the PROGRAM 
LED is no longer lit.
• Exit programming mode
and wait for the program 
LED to go out.