Timed Cycle: Press the Start/Stop button to 
begin the steaming cycle.  The display will count 
down to zero and an audio signal will sound at 
the end of the steaming cycle.
  6.  Remove steamed product.
Operating Instructions (for MS-150/250 - 
Mfg. #9100424, 432, 433, & 439 ONLY)
  1.  Turn the unit on (Figure 5b).
  2.  Allow the unit to preheat for approximately 20-30 
minutes.
NOTE: Do not push any buttons during warm-up 
time.  The flashing green ready light indicates that 
the unit is NOT up to temperature.  The flashing 
green ready light will become STEADY when the 
unit is up to temperature.
  3.  Pull out the spatula and place the product to be 
steamed onto the spatula.
  4.  Push the spatula fully into the steamer.
  5. 
Single Shot: Press and release the Single Shot 
button, wait 20 seconds for the steam to pen-
etrate the product. 
Timed Cycle: Press the Operate button to begin 
the steaming cycle.  The display will count down 
to zero and an audio signal will sound at the end 
of the steaming cycle.
  6.  Remove steamed product.
Programming
CYC (Total Cycle Time) refers to the total pro-
grammed steam time set for the product.
SHO (Shot Interval Time) is the time set between 
shots of steam during a complete cycle.
H
2
O setting (Steam Shot Time) is used to adjust the 
water volume consumed during each water pump or 
solenoid valve activation.
IMPORTANT:  208V and 220/240V Miracle Steamers 
are factory programmed for the following recom-
mended settings:
 • 
Total Cycle Time (CYC)  = 15 min., 00 secs. 
(Range: 3 seconds to 99 minutes 59 seconds)
 • 
Shot Interval Time (SHO) = 00 min., 20 secs. 
(Range: 3 seconds to 5 minutes 59 seconds)
 • 
Steam Shot Time (H
2
O) = 
MS-150/155/355 - (1_00)  
MS-250/255 - (0_70)  
(Range: 0_10 second to 2_50)
This converts approximately 3/4 oz. (25 milliliters) 
of water to steam every 20 seconds for a 15 minute 
cooking cycle.  To change any of these settings see 
PROGRAMMING on this page.
IMPORTANT:  120V Miracle Steamer is factory pro-
grammed for the following recommended settings:
 • 
Total Cycle Time (CYC)  = 2 min., 00 secs. 
(Range: 3 seconds to 99 minutes 59 seconds)
 • 
Shot Interval Time (SHO) = 00 min., 20 secs. 
(Range: 3 seconds to 5 minutes 59 seconds)
 • 
Steam Shot Time (H
2
O) = 
MS-250/255 - (0_40)  
MS-150/155/355 - (0_80) 
(Range: 0_10 seconds to 2_50)
Operating Instructions (Except MS-150/250   
Mfg. #9100424, 432, 433, & 439)
  1.  Turn the Rocker Switch (power On/Off) to ON  
(Figure 5a).
  2.  Allow the unit to preheat for approximately 20-30 
minutes.
NOTE:  Do not push any of the buttons during 
warm-up time.  The flashing green ready light indi-
cates that the unit is NOT up to temperature.  The 
flashing green ready light will become STEADY 
when the unit is up to temperature.
  3.  Pull out the Spatula or Drawer Assembly and 
place the product to be steamed onto the 
Spatula.
  4.  Push the Spatula or Drawer Assembly fully into 
the steamer.
  5. 
Single Shot: Press and release the Operate but-
ton, wait 20 seconds for the steam to penetrate 
the product. 
WARNING
To avoid injury, be careful when pulling Spatula 
or Drawer out from unit.  Be sure to allow steam 
to escape before putting hands or face over the 
steamer.
OPERATION (continued)
WARNING
To avoid injury, be careful when pulling spatula 
or Drawer out from unit.  Be sure to allow steam 
to escape before putting hands or face over the 
steamer.