TEST OF REBUILT STOP LIGHT SWITCH
Both operating and leakage tests, as indicated under
section entitiled “Testing for Serviceability”, must be made
after rebuilding or repairing the stop light switch. The switch
must meet the following specifi cations:
section entitiled “Testing for Serviceability”, must be made
after rebuilding or repairing the stop light switch. The switch
must meet the following specifi cations:
1. No leakage is permissible at the stop light switch with
the brakes applied.
2. The stop light switch contact should close with not more
than 7 pounds of air pressure.