TEST OF REBUILT STOP LIGHT SWITCH
Both operating and leakage tests, as indicated under 
section entitiled “Testing for Serviceability”, must be made 
after rebuilding or repairing the stop light switch. The switch 
must meet the following specifi cations:
1.   No leakage is permissible at the stop light switch with 
the brakes applied.
2.   The stop light switch contact should close with not more 
than 7 pounds of air pressure.