Chapter 1- Introduction
485SDA10 Features
The 485SDA10 is a general purpose control module which
operates through an RS-485 interface. The 485SDA10 offers 11
channels of 10-bit A/D (analog to digital), 3 digital inputs and 3 digital
outputs. With these features, the module can be used to sense a
variety of external conditions and to control a variety of devices.
channels of 10-bit A/D (analog to digital), 3 digital inputs and 3 digital
outputs. With these features, the module can be used to sense a
variety of external conditions and to control a variety of devices.
The 11 A/D channels allow you to measure voltages from 0 to 5
Volts. The 3 digital inputs and 3 digital outputs are CMOS/TTL
compatible. The A/D and digital I/O lines are available through a DB-
25S (female) connector.
compatible. The A/D and digital I/O lines are available through a DB-
25S (female) connector.
The 485SDA10 connects to the host computer’s RS-485 or
RS-422 serial port using terminal blocks. The address and turn-
around delays are software programmable to allow use of multiple
devices or connection to existing systems. The unit automatically
detects baud rates from 1200 to 9600. A data format of 8 data bits,
1 stop bit and no parity is used.
around delays are software programmable to allow use of multiple
devices or connection to existing systems. The unit automatically
detects baud rates from 1200 to 9600. A data format of 8 data bits,
1 stop bit and no parity is used.
Configuration parameters are stored in non-volatile memory.
The configuration parameters consist of the module address,
communication turn-around delay, and digital output power-up
states.
communication turn-around delay, and digital output power-up
states.
Figure 1.1 - 485SDA10 Unit