White Rodgers 1F89-211 White-Rodgers 80 Series Heat Pump Thermostat Manuel De Montage

Page de 8
5
 
 INSTALLER/CONFIGURATION MENU
1
 Step
Press        or        to select:
COMMENTS
Displayed (Factory Default)
Press Button(s)
2
(SL)
FA
5
6
7
8
LOC
(OFF)
on
0 HI
(0)
4 LO to
4 HI
(F)
C
10
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to F or C
4
d-L
(on)
OFF
Select display backlight OFF or ON
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
Select FA or SL (Fast or Slow) pump cycle rate
Configuration Menu
3
EMER
(FA)
SL
Select FA or SL (Fast or Slow) Auxiliary and 
Emergency Aux heating cycle rate
and
and
and
9
FA
(on)
OFF
Select fast second-stage ON or OFF
and
and
and
and
and
Set SYSTEM
switch to OFF
SYSTEM switch must be OFF to configure thermostat options
Set SYSTEM switch 
to HEAT or COOL
Returns to normal operation
* Press          and
           to advance to next item
CONFIGURATION MENU
The configuration menu allows you to set certain thermostat 
operating characteristics to your system or personal require-
ments.
Move SYSTEM switch to the OFF position, then press
 and 
 at the same time to enter the configuration menu. The 
display will show the first item in the configuration menu.
The configuration menu chart summarizes the configuration 
options. An explanation of each option follows.
Press 
 and 
 to change to the next menu item. To exit 
the menu, move the SYSTEM switch to HEAT or COOL. If no
keys are pressed within fifteen minutes, the thermostat will exit
the configuration menu.
2)  Select  FA or SL (Fast or Slow) Heat Pump stage Cycle 
Rate - The FA setting is used to produce shorter heating cycles.
The SL setting produces a longer heating/cooling cycle. Both
settings produce very accurate temperature control and can be 
set to your personal preference. FA cycles the system just under
.75°F and the SL setting cycles at approximately 1.2°F.
3)  Select FA or SL (Fast or Slow) Auxiliary or Emergency Cycle 
Rate - The FA setting is frequently used for gas, oil or electric
heat. The SL setting produces a longer heating cycle. Both set-
tings produce very accurate temperature control and can be set 
to your personal preference. FA cycles the system just under
.6°F and the SL setting cycles at approximately 1.°F.
4) Select backlit display (d-L OFF or ON) - The display 
backlight improves display contrast in low lighting conditions.
Selecting backlight ON will keep the light on continuously.
Selecting OFF will keep the light off.
5)  Select filter replacement run time - The thermostat will 
display 
FILTER after a set time of operation. This is a re-
minder to change or clean your air filter. This time can be 
set from 0 to 1950 hours in 50 hour increments.
A selection 
of 000 will cancel this feature. When FLTR is displayed, 
you can clear it by pressing 
 and 
 at the same time. 
This resets the timer and starts counting the hours until the 
next filter change. Contact your heat pump manufacturer for
a specific replacement/maintenance interval.
6)  Select Compressor Lockout (LOC OFF or ON) - Selecting
LOC ON will cause the thermostat to wait 5 minutes before
turning on the compressor if the heating and cooling system 
loses power. It will also wait 5 minutes minimum between cool-
ing cycles. This is intended to help protect the compressor from 
short cycling. Some newer compressors already have a time
delay built in and do not require this feature. Your compressor 
manufacturer can tell you if the feature is already present in 
their system. When the thermostat compressor time delay 
occurs it will flash the 
Snowflake or Flame icon for about 
five minutes. 
7)  Select Temperature Display Adjustment (4 LO to 4 HI) - 
Allows you to adjust the room temperature display up to 4°
higher or lower. Your thermostat was accurately calibrated 
at the factory but you have the option to change the display 
temperature to match your previous thermostat. The current 
or adjusted room temperature will be displayed on the right 
side of the display. 
8)  Select Temperature Display (°F or °C) - Changes the display
readout to Celsius or Fahrenheit as required. The current
room temperature will be displayed on the right side of the 
display. 
9)  Select Fast second stage - In the RUN mode, if the tem-
perature  is  manually  raised  by  3°F  (2°C)  or  more  above
room temperature using 
 and the fast second stage 
feature is enabled, FA on, the second stage will energize
immediately. With FA off, the second stage will not energize
until the setpoint temperature is 10°F or more above room
temperature.