White Rodgers 3049-115 Mercury Flame Sensors Catalogue

Page de 1
 
Model 
Element  Panel 
Bulb
 
Number 
Length 
Type 
Style 
Description
 
3049-115 ➀ 
48” 
#20 
Replaces bulb styles #17 or #18
 
3098-134 ➀ 
48” 
#19 
Replaces bulb styles #9 or #13
 
3098-156 ➀ 
48” 
#20 
Replaces bulb styles #17 or #18
 
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .  
C.S.A. approved
Maximum temperature . . . . . . . . . . . . . . .   1450°F at bulb tip
MERCURY FLAME SENSORS
For Proving Pilot Flame and Controlling Main Valve in 
Cycle Pilot Applications
FEATURES
• Bulb styles are designed to fit with various OEM applications.
• See Cross Reference to OEM control type numbers on next page.
• Adapter fittings to allow use of these mercury flame sensors with competitive
 burners are packed with controls identified with ➀.
3098-134
 
Model Number 
30VAC 
120VAC 
240VAC
 
3098-522 
30VA 
125VA 
125VA
 
All others listed 
3A 
1A 
0.5A
ELECTRICAL RATINGS
GAS BURNER
CONTROLS
 Includes adapter fittings.
CONTRACTOR TIP: Mercury flame
sensors can only be replaced by cross
referencing the original mercury flame
sensor model number. They can not be
replaced by gas valve model number.
See next page.
www.white-rodgers.com
62
HEA
TING