Каталог для White Rodgers 3049-115 Mercury Flame Sensors
Model
Element Panel
Bulb
Number
Length
Type
Style
Description
3049-115 ➀
48”
D
#20
Replaces bulb styles #17 or #18
3098-134 ➀
48”
E
#19
Replaces bulb styles #9 or #13
3098-156 ➀
48”
E
#20
Replaces bulb styles #17 or #18
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .
C.S.A. approved
Maximum temperature . . . . . . . . . . . . . . . 1450°F at bulb tip
MERCURY FLAME SENSORS
For Proving Pilot Flame and Controlling Main Valve in
Cycle Pilot Applications
FEATURES
• Bulb styles are designed to fit with various OEM applications.
• See Cross Reference to OEM control type numbers on next page.
• Adapter fittings to allow use of these mercury flame sensors with competitive
burners are packed with controls identified with ➀.
3098-134
Model Number
30VAC
120VAC
240VAC
3098-522
30VA
125VA
125VA
All others listed
3A
1A
0.5A
ELECTRICAL RATINGS
GAS BURNER
CONTROLS
➀
Includes adapter fittings.
CONTRACTOR TIP: Mercury flame
sensors can only be replaced by cross
referencing the original mercury flame
sensor model number. They can not be
replaced by gas valve model number.
See next page.
www.white-rodgers.com
62
HEA
TING