IMC Networks McPC 100 Mbps Manuel D’Utilisation

Page de 12
5 
Enabling TX and FX LinkLoss 
In order to enable the LinkLoss features, remove the cover from the unit and place 
the jumpers accordingly.  Follow the instructions below, referencing the diagram. 
 
1.  Make sure that there is no power going to the unit by UNPLUGGING THE 
POWER CORD. 
2.  Using a Philllips screwdriver, remove the screws on the corners of the cover. 
3.  Remove the cover and find the three-pin jumper blocks for TX and FX LinkLoss.  
Adjust the shunts on the jumpers accordingly. 
4.  Replace the cover and tighten the screw to secure the cover. 
 
Refer to the following diagrams and table for jumper location and settings. 
Using FiberAlert and LinkLoss 
The following table provides an overview of the troubleshooting features, their 
functionality and the recommended settings for a pair of media converters in a typical 
central/main site to remote site application: 
 
LinkLoss/FiberALert Compared 
Feature 
Fault Location 
Disabled LEDs 
Enable At: 
FX LinkLoss 
Fiber 
Twisted Pair 
Main Site Only 
TX LinkLoss 
Twisted Pair 
Fiber 
Remote Site Only 
FiberAlert 
Fiber Fiber Remote 
Site 
Only 
 
This will ensure that any faults, no matter where they occur, can be detected by a 
administrator located at the central site.  
Enabling FiberAlert 
Configure FiberAlert on McPC 100Mbps by adjusting a two-position switch, labeled 
FA, on the faceplate next to the fiber connectors.  Enable this feature by moving the 
switch to the up ON position.  Disable by moving the switch to the down OFF 
position (default).