IMC Networks McPC 100 Mbps Manuel D’Utilisation

Page de 12
6 
Installation Troubleshooting 
ƒ 
During installation, first test the fiber and twisted pair connections with 
FiberAlert disabled.  Then enable FiberAlert, if desired, just before final 
installation.  This will reduce the feature’s interference with testing. 
 
ƒ 
To test McPC 100Mbps by itself, use the appropriate fiber patch cable.  First, 
connect McPC 100Mbps to the twisted pair device with a twisted pair cable.  
Next, look a single strand of fiber from the transmit port to the receive port of 
the media converter.  Finally, verify that there are both twisted pair and fiber link 
on the media converter. 
Specifications 
Environmental 
Operating Temperature 
32° - 104° F (0° - 40° C) 
Storage Temperature 
21° - 160° F (-6° - 71° C) 
Humidity:   
5 - 95% (non-condensing) 
Electrical 
Input Load 
100/240V±10% ~ 50/60Hz, 0.1/0.05A 
Dimensions 
A single PCI slot module for use in a PC chassis. 
 
 
IMC Networks Technical Support 
 Tel:   (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); 
  
+32-16-550880 
(Europe) 
 Fax:   (949) 465-3020 
 E-Mail:  
techsupport@imcnetworks.com
 
 Web:  
www.imcnetworks.com