Empire Comfort Systems pmn Manuel D’Utilisation

Page de 28
Page 18
15627-4-0806
CIBV-30 ON/OFF/REMOTE Switch
CIBV-30 is equipped with an ON/OFF/REMOTE switch which 
is located on the wire channel. A wire harness is attached to the 
ON/OFF/REMOTE switch. The red, black and green (wires) female 
push-ons attach to the ON/OFF/REMOTE switch. At the opposite 
end of the wire harness, the black and green (wires) female push-
ons attach to the gas valve. An additional green wire and the red 
wire, which are stripped and bare, will attach to the 750 millivolt 
wall thermostat  accessory, or, to one of the other accessories that 
can be purchased for use with your log set. 
Operation  of  ON/OFF/REMOTE  Switch  with  no 
Accessories 
To ignite main burner, turn the control knob on the gas valve 
from the PILOT position to the ON position. Turn the ON/OFF/
REMOTE switch from the OFF position to the ON position. The 
additional green wire and red wire, which are stripped and bare 
are not used.
Operation of ON/OFF/REMOTE Switch with Accessories
750 Millivolt Wall Thermostat
Connect the green and red, stripped and bare, wires on the ON/
OFF/REMOTE switch wire harness to the wall thermostat. Turn the 
ON/OFF/REMOTE switch on the wire channel to the REMOTE 
position. Set the wall thermostat to the desired temperature. 
It is important to use wire of a gauge proper for the length of the 
wire:
RECOMMENDED WIRE GAUGES
 
Maximum 
Wire
 
Length 
Gauge 
 
1' to 10' 
18
 
10' to 25' 
16
 
25' to 35' 
14
Wall Switch, FWS-1
Connect  the  green  and  red,  stripped  and  bare,  wires  on  the 
ON/OFF/REMOTE  switch  wire  harness  to  the  wall  switch. 
Turn the ON/OFF/REMOTE switch on the wire channel to the 
REMOTE position. Pivot the rocker switch on the FWS-1 to the 
ON position.  
Battery Operated Remote Control, FRBC-1 and FRBTC-1
Connect the green and red, stripped and bare, wires on the ON/
OFF/REMOTE switch wire harness to the remote receiver that 
is a component in the FRBC-1 and FRBTC-1. Turn the ON/OFF/
REMOTE switch on the wire channel to the REMOTE position. 
Follow instructions in the FRBC-1 and FRBTC-1 to complete 
installation. 
Note: If batteries fail in FRBC-1 or FRBTC-1, and immediate heat 
is desired, turn the ON/OFF/REMOTE switch on wire channel 
from the REMOTE position to the ON position. 
Electric (120 volt) Operated Remote Control, FREC-1
Connect the green and red, stripped and bare, wires on the ON/
OFF/REMOTE switch wire harness to the wires on remote receiver 
that is a component in the FREC-1. Turn the ON/OFF/REMOTE 
switch  on  the  wire  channel  to  the  REMOTE  position.  Follow 
instructions in the FREC-1 to complete installation.
Note: If electric (120 volt) fails in FREC-1, and immediate heat 
is desired, turn the ON/OFF/REMOTE switch on wire channel 
from the REMOTE position to the ON position. 
Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall 
Thermostat Accessory and Another Accessory
Connect the green and red, stripped and bare, wires on the ON/
OFF/REMOTE  switch  wire  harness  to  the  750  millivolt  wall 
thermostat AND to the remote receiver that is a component in the 
FRBC-1, FREC-1 OR to the FWS-1, wall switch.
1. Connect (1) wire from the 750 millivolt wall thermostat and 
(1) wire from appropriate accessory to the GREEN, stripped 
and bare wire from the ON/OFF/REMOTE wire harness.
2. Connect (1) wire from the 750 millivolt wall thermostat and 
(1) wire from appropriate accessory to the RED, stripped and 
bare wire from the ON/OFF/REMOTE wire harness.
  Note: When the appliance is in the MANUAL mode and the 
batteries fail in the FRBC-1 or if the electric (120 volt) fails in 
the FREC-1, and immediate heat is desired, turn the ON/OFF/
REMOTE switch on wire channel from the REMOTE position 
to the ON position.
Manual Operation
1. Turn ON/OFF/REMOTE switch on wire channel to REMOTE 
position.
2. Turn wall thermostat OFF.
3. Turn accessory, FRBC-1, FREC-1 or FWS-1, ON. Appliance 
is now in the manual mode. You must turn the appliance ON 
or OFF with appropriate accessory.
Wall Thermostat Operation
1. Turn  the  ON/OFF/REMOTE  switch  on  wire  channel  to 
REMOTE position.
2. Turn accessory, FRBC-1, FREC-1 or FWS-1, OFF.
3. Turn wall thermostat ON and set appropriate temperature. Wall 
thermostat will cycle the appliance ON and OFF.
WIRING