Chapter 5: Program Parameter Descriptions 
38 of 55 
 
Parameter 36 – Signal Input 2 (S2) Setpoint 
When the S2 configuration, parameter 35, is set to one of the jog modes, this parameter 
defines the jog setpoint in display units.  If the drive operating mode is set to Follower Mode, 
then this parameter is set in RPM units.  This allows a follower control to be jogged when the 
master is stopped. 
 
Parameter 37 – Signal Input 2 (S2) Pulses per Revolution 
This is the number of pulses per revolution for the signal input 2 (S2).  The drive supports 
pickups and encoders from 1 to 2048 pulses per revolution. 
 
Parameter 95 – Factory Default Command 
When set to a value of 5, the unit will be reset to factory default settings.  This can also be 
achieved by applying power to the unit with both the Enter and Down buttons depressed.  The 
programming jumper must be in the "On" position for this method to function. 
 
Parameter 98 – Save to User Default Area Command 
When set to a value of 5, the unit will store all adjustable parameters to the user default area.  
The user default area is intended to be a location where an end user can store settings specific 
to their application.  Using this, an end user can easily refresh their custom settings in the 
field if an someone accidentally reconfigures the unit unsuccessfully.  Another common use 
for this area is testing and initial setup.  The user can store known-good settings here and 
easily experiment without the fear of losing the optimal configuration. 
 
Parameter 99 – Restore from User Default Area Command 
When set to a value of 1, the unit will restore the all adjustable parameters from the user 
default area.  See parameter 98 for additional information.