Commissioning
9.2 Procedure
3. Select the motor
Before the motor is selected, message 300701 "Commissioning required" must appear; see
screenshot below.
a) The torque motor appears in the list → Select the motor
Figure 9-3
Selection of a motor for which data has already been defined
b) The torque motor does not appear in the list
→ Select "NonSiemens mot.", enter the relevant data in the "Motor" field
→ Select "NonSiemens mot.", enter the relevant data in the "Motor" field
Note
If a lower identification current is required (< 40%), bit 5 should be used to hide alarm
If a lower identification current is required (< 40%), bit 5 should be used to hide alarm
300753 in MD 1012.
1FW6 Built-in torque motors
172
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7