(0) For the Arbitrator version 1.8(or earlier) Users
-How to upgrade to version 1.9?-
If you have the version 1.8 or earlier of Arbitrator, it is necessary to 
upgrade both SI 
(Front End Application) and VPU firmware to the version 1.9 
as the following procedure.
[Step 1] 
Upgrade VPU firmware FIRST by SI version 1.8 or earlier 
you currently run on PC.
1) 
Please save the VPU firmware for the version 1.9 to the USB memory or P2 card.
2) 
Connect that USB memory or P2 card to VPU and by SI menu, go to “Config”, “Operations” and press 
“Version up” to upgrade the VPU firmware.
USB Memory*
VPU 
Firmware
For Ver. 1.9
Save
[Step 2] 
Then, Upgrade to SI version 1.9
After upgrading the VPU firmware as [Step 1], please uninstall the SI you currently run and install the new SI version 1.9. 
REMARK
Procedure
Duration
(Sec)
LED Display
REC
READY
BUSY
1) 
Keep pressing “STOP” button for 15 
sec
15
OFF
OFF
OFF
2) Updating process for VPU microcomputer
45
ON
Flash
ON
3) Update complete
---
Flash
ON
Flash
4) 
Press “STOP” button to restart
---
Flash
Flash
Flash
5) Updating process for Front microcomputer
150
Flash
ON
ON
6) Version up complete
---
OFF
OFF
OFF
REC LED
(
RED
)
READY LED
(
Green
)
BUSY LED
(
RED
)
If upgrading to SI version 1.9 first, you cannot operate the VPU because VPU firmware is still version 1.8 or earlier.  
Therefore, in order to upgrade the VPU firmware, please follow the above [Step1] 1).   Connect the USB memory or P2 card to VPU.
Leaving  the P2 card slot open
, follow the procedure in the chart below.
*When some USB memory 
may not work, please use 
the different USB memory.