BENDIX SD-61-4933 Manuel D’Utilisation

Page de 20
5
Parallel with 
the Ground
FIGURE 5 - inStallation of SenSor
1.4  OPERaTOR DISPlay UNIT mOUNTING
The Bendix BlindSpotter Operator Display Unit (ODU) 
should be mounted on a windshield pillar for the side of 
the vehicle being monitored - see Figure 6.  
Mount on 
Windshield 
Pillar
FIGURE 6 - inStallation of odU
The Bendix BlindSpotter Operator Display Unit has a 
bracket that is designed to be bent up to fifteen (15) degrees 
in order to optimize the angle for the driver’s view.
1.1 RaNGE
See Figure 2.  The effective range is approximately ten (10) 
feet out from the vehicle and the detection zone extends 
seven and a half feet forward and backward from the 
sensor.
1.2  SENSOR lOCaTION
The Bendix
 BlindSpotter
®
 Side Object Detection Sensor 
must be mounted on the side of the vehicle, between 22 
and 36 inches from the ground and at least 18 inches rear 
of the side view mirror (See Figure 4).
Note: To reduce the possibility of the sensor detecting 
objects mounted to the vehicle — like the steps or fuel 
tanks — make sure the face of the sensor extends out a 
minimum of 5/16 of an inch further than any other object 
within six (6) inches of the sensor’s body.
1.3  SENSOR ORIENTaTION
The Bendix BlindSpotter Sensor should be mounted on a 
vertical surface and oriented so that the embossed logo 
is parallel to the ground — you may use the lower two 
mounting holes as a guide - see Figure 5.  Orientation is 
crucial for proper operation due to the radar’s polarized 
beam profile.