Elica ESR436SS Manuel De Montage

Page de 32
8
Set free the two blower springs from the top of the range hood 
housing.
Flip the blower base to the rear face of the range hood.
Insert the two blower springs to the top of the range hood      
housing, Secure it with the four mounting screws previously 
released.
Installation to wall
Install framing for hood support
If drywall is present, mark the screw hole locations. Remove the 
template.
Cut away enough drywall to expose 2 vertical studs at the holes 
location indicated by the template. Intall two horizontal supports 
at least 4” x 2” between two wall studs at the bottom and upper 
mounting holes installation location.
The horizontal support must be flush with the room side of the 
studs. Use cleats behind both sides of the support to secure wall 
studs.
Reinstall dywall and refinish.
IMPORTANT:Framing must be capable of supporting 100 lbs.
 
 
View from rear 
1” x 6” Min.
Mounting  
Support
Centerline of 
Installation 
Space
Cleats
Cut holes at marked locations for duct and electrical wiring.
For the vertical duct, cut out
 3⁄ 4
” extra toward the front of the cabi-
net so you can move the dut freely when installing the hood.
It may also easy installation by cutting the hole 10
1⁄2
” instead of 
10”.
Install Range hood
Drive a mounting screw (from the hardware package) partway 
into each center of the narrow neck of the keyhole slots marked 
on the cabinet bottom or the wall’s support frame.
Install the 2 (wall installation) or 4 (cabinet installation 5 x 45 mm 
mounting screws. Leave a 
1⁄4
” (6.4 mm) gap between the wall 
and the back of the screw head to slide range hood into place.
1
4
(6.4 mm)
1
4
(6.4 mm)
Wall Installation
Cabinet Installation
Fix the wiring conduit of the hood.
Slide the hood back against the cabinet/wall. Tighten the          
mounting screws. Be sure the screw heads are in the narrow 
neck of the keyhole slot.
• 
In wall installations, mount the security screws as shown in the 
 
image below.
Cabinet Installation
A
Wall installation
A
C
B
C
A. Mounting Screws
B. Lower security screws (Wall Installation)
C. Upper security screws (Wall Installation)
Connect Ductwork to hood.