Figure 2
Ground
Receptacle
Opening for
Power Cord
4  HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust 
duct is required. All ductwork must be metal; absolutely 
do not use plastic duct. Check that all connections are 
made securely. Please read the following carefully: 
Exhaust  connection:  The  hood  exhaust  has  been 
designed to connect to a standard 3-1/4” X 10” rect-
angular duct. If round duct is required, a rectangular-
to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be 
used, care should be taken to align the exhaust with the 
space between the studs, or wall should be prepared 
at the time it is constructed by leaving enough space 
between wall studs to accommodate exhaust.
Maximum duct length: For satisfactory air movement, 
the total duct length of 3-1/4” X 10” rectangular or 6” 
diameter round duct should not exceed 140 feet.
Elbows,  adapters,  wall  caps,  roof  caps,  etc.  present 
additional resistance to air flow and are equivalent to a 
section of straight duct which is longer than their actual 
physical size. When calculating the total length, add the 
equivalent lengths of all transitions and adapters plus 
the length of all straight duct sections. Figure 3 shows 
the approximate feet of equivalent length of some typi-
cal ductwork parts. Use the values in parentheses for 
calculating air flow resistance equivalent, which should 
total less than 140 feet.
3  ELECTRICAL GROUNDING 
INSTRUCTIONS
This appliance must be grounded. This oven is equipped 
with a cord having a grounding wire with a grounding 
plug. It must be plugged into a wall receptacle that is 
properly  installed  and  grounded  in  accordance  with 
the  National  Electrical  Code  and  local  codes  and 
ordinances. In the event of an electrical short circuit, 
grounding reduces risk of electric shock by providing 
an escape wire for the electric current.
WARNINGImproper use of the grounding plug can 
result in a risk of electric shock.
E
LECTRICAL
 R
EQUIREMENTS
The oven is equipped with a 3-prong grounding plug. 
DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE-
MOVE THE GROUNDING PIN FROM THE PLUG.
The Power Supply Cord and plug must be connected to 
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch 
circuit,  single  grounded  receptacle.  The  receptacle 
should  be  located  inside  the  cabinet  directly  above 
the Convection Microwave Hood mounting location as 
shown in Figure 2.
NOTE:
1. If  you  have  any  questions  about  the  grounding  or 
electrical instructions, consult a qualified electrician 
or serviceperson.
2. Neither Viking nor the dealer can accept any liability 
for damage to the oven or personal injury resulting 
from failure to observe the correct electrical connec-
tion procedures.