Viking VMOR205SS Instrução De Instalação
2
Figure 2
Ground
Receptacle
Opening for
Power Cord
4 HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust
duct is required. All ductwork must be metal; absolutely
do not use plastic duct. Check that all connections are
made securely. Please read the following carefully:
Exhaust connection: The hood exhaust has been
Exhaust connection: The hood exhaust has been
designed to connect to a standard 3-1/4” X 10” rect-
angular duct. If round duct is required, a rectangular-
to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be
Rear exhaust: If a rear or horizontal exhaust is to be
used, care should be taken to align the exhaust with the
space between the studs, or wall should be prepared
at the time it is constructed by leaving enough space
between wall studs to accommodate exhaust.
Maximum duct length: For satisfactory air movement,
Maximum duct length: For satisfactory air movement,
the total duct length of 3-1/4” X 10” rectangular or 6”
diameter round duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present
Elbows, adapters, wall caps, roof caps, etc. present
additional resistance to air flow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total length, add the
equivalent lengths of all transitions and adapters plus
the length of all straight duct sections. Figure 3 shows
the approximate feet of equivalent length of some typi-
cal ductwork parts. Use the values in parentheses for
calculating air flow resistance equivalent, which should
total less than 140 feet.
3 ELECTRICAL GROUNDING
INSTRUCTIONS
This appliance must be grounded. This oven is equipped
with a cord having a grounding wire with a grounding
plug. It must be plugged into a wall receptacle that is
properly installed and grounded in accordance with
the National Electrical Code and local codes and
ordinances. In the event of an electrical short circuit,
grounding reduces risk of electric shock by providing
an escape wire for the electric current.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock.
E
LECTRICAL
R
EQUIREMENTS
The oven is equipped with a 3-prong grounding plug.
DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE-
MOVE THE GROUNDING PIN FROM THE PLUG.
The Power Supply Cord and plug must be connected to
The Power Supply Cord and plug must be connected to
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch
circuit, single grounded receptacle. The receptacle
should be located inside the cabinet directly above
the Convection Microwave Hood mounting location as
shown in Figure 2.
NOTE:
NOTE:
1. If you have any questions about the grounding or
electrical instructions, consult a qualified electrician
or serviceperson.
2. Neither Viking nor the dealer can accept any liability
for damage to the oven or personal injury resulting
from failure to observe the correct electrical connec-
tion procedures.
Figure 3