Maytag UXD86DYS Manuel De Montage

Page de 36
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools Needed
Jigsaw or keyhole saw
Drill
¹⁄₈" (3 mm) drill bit for pilot holes
Pencil
Tape measure or ruler
Flat-blade screwdriver
Phillips screwdriver
³⁄₈" (9.5 mm) nut driver
Level
Pliers
Metal snips
Wire stripper or utility knife
Caulking gun and weatherproof caulking compound
Parts Supplied
Top trim—stainless
End caps (2)
Lower support legs (2)
Undercounter mounting brackets (2)
4 x 8 mm screws (16)
3.5 x 9.5 mm screws (3)
3
¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper
4
³⁄₄" (12.0 cm) motor box
¼" (6.4 mm) deep cover
Flat vent cover plate 
6" (15.2 cm) diameter vent transition with damper
Parts Needed
UL listed or CSA approved ½" (12.7 mm) conduit connector
Wall or roof cap with damper to match vent system
Vent system
Home power supply cable
UL listed wire connectors (3)
Vent clamps/duct tape as required
Location Requirements
NOTE: Downdraft vent is installed directly behind the cooktop. 
Install the downdraft vent first, then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the downdraft vent. It is the 
installer’s responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial 
rating plate is located on the front of the downdraft vent 
above the terminal box cover.
Downdraft vent location should be away from strong draft 
areas, such as windows, doors, and strong heating vents or 
fans.
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance. 
Consult the cooktop manufacturer installation instructions 
before making any cutouts. 
Check that the downdraft vent and cooktop location will 
clear the cabinet walls, backsplash, and rear wall studs 
inside the cabinet. 
Check for the minimum distance between the front edge 
of the countertop and the front edge of the cooktop. The 
minimum horizontal distance between the overhead 
cabinets is the same as the width of the installed 
downdraft vent.
All openings in ceiling and wall where the downdraft vent will 
be installed must be sealed.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
When installing the downdraft vent, the cabinet drawer will 
need to be removed and the drawer front installed 
permanently to the cabinet.
Cabinet Construction:
Downdraft vent is designed for use in a cabinet with a depth of 
24" (61 cm). Some installations require a countertop deeper than 
25" (63.5 cm). See the “Countertop Cutout Dimensions Chart.”
The maximum depth of the overhead cabinet is 13" (33 cm). 
Overhead cabinets installed at either side of the downdraft vent 
must be 18" (45.7 cm) above the cooking surface.
For Mobile Home Installations
The installation of this downdraft vent must conform to 
the Manufactured Home Construction Safety Standards, 
Title 24 CFR, Part 328 (formerly the Federal Standard for 
Mobile Home Construction and Safety, title 24, HUD, Part 280) 
or when such standard is not applicable, the standard for 
Manufactured Home Installation 1982 (Manufactured Home 
Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or 
latest edition, or with local codes.