Crossover DAWF0EM Manuel Du Propriétaire

Page de 38
4
Laundrylux
112999-1
ANTI-WRINKLE
This program selection helps keep permanent press items
wrinkle free when they are not removed from the dryer promptly
at the end of the drying and cooling cycles.  The Anti-Wrinkle
program settings are:
1. Guard Delay Time ..............1 to 9 minutes
2. Guard On Time ...................1 to 99-seconds
3. Active Guard Time..............1 to 99 minutes
FREE DRY MODE
In this program selection, the dryer can be started without the
insertion of coins by simply pressing any one of the three
temperature selections.  When set in the “Free Dry” Mode,
the Phase 5 coin microprocessor controller (computer) can
also be programmed to run with an Automatic Cycle (percent
of dryness) or with a Timed Cycle.  If the “Free Dry” program
is utilized, the computer ’s L.E.D. display will cycle back and
forth between “FILL” to “FrEE,” unless otherwise programmed.
L.E.D. FLASH DISPLAY
Programmable to allow the L.E.D. readout to display a choice
of “FILL” (no cycle in progress), “Amount To Start” (i.e., 25¢),
or, in the case of free dry, “FrEE.”  This program selection also
allows the L.E.D. display to flash back and forth every
2-seconds from “FILL” to “Amount To Start” or, in the case of
free dry, from “FILL” to “FrEE.”
AUDIBLE TONE
In this program selection, a tone (buzzer) will sound for each
coin inserted, program entry, or at the drying and cooling cycles
for a period of 5-seconds to indicate that the cycle is complete.
Additionally, when in the  Anti-Wrinkle program, the tone
(buzzer) will sound for 5-seconds at the end of the “Guard On
Time.”
TEMPERATURE DISPLAY
This program selection enables the temperature in the dryer
to be viewed (°F or °C) either while the dryer is off or running.
This service feature shows that the dryer is maint aining the
selected temperature.
DIAGNOSTICS
All major circuits, including door, microprocessor temperature
sensor, heat, and motor circuit s are monitored.   There are
also indicators installed on the outputs of each relay to easily
identify failures, and the door switch has an indicator installed
on the Phase 5 microprocessor controller (computer) to help
indicate failure.
AUTOMATIC DRY TIME
This program selection allows the dryer to run up to a specific
time.  During the “AUtO” mode or “FrEE” dry mode this program
is only designed to limit the dryer’s operation during the drying
cycle.
ROTATIONAL SAFE GUARD (Optional)
This program monitors the rotation of the tumbler.  If the tumbler
is not rot ating, the Phase 5 coin microprocessor controller
(computer) will disable all output s, an audible tone (buzzer)
will sound, and an error message will be displayed.  
This
program selection can be programmed to be in the inactive
mode.
BATTERY BACKUP (Optional)
This feature allows the Phase 5 coin microprocessor controller
(computer) to maintain its operating status should a momentary
power interruption occur while the dryer cycle is in progress.
L.E.D. Display and Codes _____________
A
Automatic Cycle (Slope Program Factor)
ACOn
Accumulative Coin
Adrt
Maximum Auto Dryness Time
AFAt
Amount for Additional Time
AGt
Active Anti-Wrinkle Guard Time
AtIn
Accumulative Time
AtSt
Amount To Start
AUtO
Automatic Mode (Patent No. 4,827,627)
b
Automatic Cycle (Heat Loss [of fset] Factor)
bCLO
Bad Coin Lockout
bCrS
Bad Coin Reset
bUZ
Buzzer (Tone)
°CEL
Degree in Celsius
CLCC
Clear Left Coin Count
Coin
Coin Mode
CrCC
Clear Right Coin Count
donE
Drying and Cooling Cycles Complete
or
Dryer is in Anti-Wrinkle Cycle
door
Door Circuit is Open*
dSFL
Dryer Sensor Circuit Failure*
°FAr
Degree in Fahrenheit
FILL
No Cycle in Progress
FLS
Flash Display Active
FrEE
Free Dry Mode
GdLY
Anti-Wrinkle Delay Time
Gont
Anti-Wrinkle On Time
Grd
Anti-Wrinkle Program Active
HICd
High Cool Down
Hot
Overheating Condition*
LCC
Left Coin Count
LCdE
Left Coin Denomination
LOCd
Low Cool Down
nbUZ
No Buzzer (Tone)
nFLS
No Flash Display
nGrd
No Anti-Wrinkle
nSEn
No Rotational Sensor Selected
PdrY
Percent Dry
PL
Program Location
PLOC
Program Location Automation Review
PPCd
Permanent Press Cool Down
PP°F
Permanent Press
PUSH
Amount to start has been Inserted
Make Temperature Selection
rCC
Right Coin Count
rCdE
Right Coin Denomination
SEFL
Rotational Sensor Circuit Failure*
SEn
Rotational Sensor Selected
tFAS
Time For Amount to Start
tInE
Timed Mode
* Refer to Phase 5 Coin System Diagnostics on page 36 for detailed information.