10. Mount Range Hood 
Lift the range hood into place, positioning the rear slots over 
the mounting brackets.
Using a Phillips screwdriver, push on the screws that are 
started into the top mounting tabs and bend the tabs against 
the cabinet side walls. Attach the screws to the cabinet side 
walls.
For direct wire installations, run the home power supply cable 
according to the National Electric Code or CSA standards 
and local codes and ordinances. There must be enough 
wiring from the fused disconnect (or circuit breaker) box to 
make the connection in the range hood electrical terminal 
box. 
Tighten the strain relief screws.
NOTE: Do not reconnect power until the installation is 
complete.
OPTIONAL: If you prefer, bend the rear tabs against the rear 
of the range hood and attach to the wall using #8-18 x 
⁵⁄₈" 
(4.2 x 16 mm) truss-head screws.
11. Connect Vent System
Connect the ventwork to the range hood. Seal joints with vent 
clamps or duct tape to make secure and airtight.
Check that the back draft dampers work properly.
12. Make Electrical Connection
Option 1 - Direct Wire Installations 
Use a UL Listed/CSA Approved wire connector and connect 
the 2 white wires (A) together.
Use a UL Listed/CSA Approved wire connector and connect 
the 2 black wires (B) together.
Connect the green (or bare) ground wire (C) from the power 
supply to the green ground screw in the electrical box and 
tighten the screw securely.
Reinstall the electrical box cover.
Reconnect power.
Option 2 - Power Cord Kit Installations 
For optional power cord kit installations, follow the instructions 
supplied with the power cord kit. See the “Assistance or Service” 
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have 
been investigated and found acceptable for use with this model 
range hood.
13. Complete the Installation
Install a 120V, 75W maximum, incandescent light bulb with 
E26 base. See “Replacing the Incandescent Light Bulb” in the 
“Range Hood Care” section.
If removed previously, replace the filter. See “Metal or Charcoal 
Grease Filter” in the  “Range Hood Care” section.
For vented installations: Install a metal filter.
For non-vented (recirculating) installations: Install a  
charcoal filter. 
Check the operation of the range hood fan and light. See the 
“Range Hood Use” section.
If the range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
Disconnect the power and check the wiring connections. 
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
A
B
C
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in 
terminal box.
Failure to do so can result in death, fire, or 
electrical shock.