Emerson MMI-20019043 Manuel D’Utilisation

Page de 374
Effects of Update Rate = Special
Incompatible features and functions
Special
 mode is not compatible with the following features and functions:
Enhanced events. Use basic events instead.
All calibration procedures.
Zero verification.
Restoring the factory zero or the prior zero.
If required, you can switch to Normal mode, perform the desired procedures, and then
return to Special mode.
Process variable updates
Some process variables are not updated when Special mode is enabled.
Special
 mode and process variable updates
Table 5-1:   
Always polled and updated
Updated only when the petroleum
measurement application is disa-
bled
Never updated
Mass flow
Volume flow
Gas standard volume flow
Density
Temperature
Drive gain
LPO amplitude
Status [contains Event 1 and Event
2 (basic events)]
Raw tube frequency
Mass total
Volume total
Gas standard volume total
Temperature-corrected volume
total
Temperature-corrected density
Temperature-corrected volume
flow
Batch-weighted average tempera-
ture
Batch-weighted average density
RPO amplitude
Board temperature
Core input voltage
Mass inventory
Volume inventory
Gas standard volume inventory
All other process variables and calibra-
tion data. They retain the values held
at the time you enabled Special mode.
Configure device options and preferences
88
Micro Motion
®
 Model 2700 Transmitters with Analog Outputs