28
u
4.7 OPERATION AT FULL CACHE (RECORDING TIME)
The OM-550 includes a battery-backed, 28-Kb data cache. The cache is erased when
the RUN or PROG keys are pressed and new data is stored during logging. The OM-
550 can be programmed to stop when the data cache is full or to log continuously and
overwrite the oldest data when the cache fills.
When the RUN key is pressed, the selected operation and the time required to fill the
cache is displayed. In this example, the unit will stop on a full cache:
Figure 4-5
Operation at full cache is determined during programming. To program the OM-550 to
stop logging when the cache is full, answer the programming prompts as follows:
Figure 4-6
RUN
 KEY PRESSED
CACHE FULL IN 2 DAYS, 10 HRS, and 20 MIN.
PRESS 
YES
OM-550 LOGS & PRINTS THE
 
TIME, DATE &
FIRST DATAPOINTS
PROG
OK
 KEYS PRESSED
PRESS 
OK
PRESENTLY SET TO OVERWRITE FULL CACHE
PRESS 
YES
EXIT
THE SELECTION IS ECHOED
PRESS THE 
EXIT
 KEY AND IT IS ECHOED
THE TIME, DATE AND MENU PRINT