Furuno GP32 Manuel D’Utilisation

Page de 88
8. MAINTENANCE & TROUBLESHOOTING 
 
48 
8.3  Replacing the Fuse 
The fuses (type: FGMB 125V 1A PBF, code 
no.: 000-157-478-10) in the power cable (+/- 
lines) protects the equipment from 
overcurrent, reverse polarity of the power 
source and equipment fault. If the fuse blows, 
find the cause before replacing the fuse. If the 
fuse blows again after replacement, request 
service.  
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment.
 
 
 
8.4  Replacing the Battery 
A lithium battery (type: CR2354-1F2, code 
no.: 000-142-305) on the circuit board inside 
the display unit preserves data when the 
power is turned off. The life of the battery is 
3-5 years. When its voltage is low, the 
message shown below appears and data is 
transferred from the RAM to the flash 
memory. 
BATTERY ALARM!
INTERNAL BATTERY
VOLTAGE IS LOW.
REPLACE BATTERY.
PUSH ENTER KEY TO
BACKUP WPTS,
ROUTES & TRACKS.
 
Low battery voltage warning 
When this message appears, all open 
windows are closed, no alarm will be 
generated and no key input other than the 
[ENT] key is accepted. Press the [ENT] key to 
back up data and then turn off the power. 
Contact your dealer to request replacement 
of the battery. Below is the procedure for 
replacing the battery. 
 
1.  Turn on the power and then press the 
[MENU] key once or twice to open the 
menu. 
2  Choose SYS SETUP and then press the 
[ENT] key. 
SYSTEM SETUP
LANGUAGE  :  
ENGLISH
DATUM
    :
 
 WGS84
UNITS
    :  nm, kt
TIME DIFF
    :  +00 : 00
TIME DISP       :  24HOUR
TEST?
SIMULATOR?
EXCHANGE BATTERY?
 
SYSTEM SETUP menu 
3.  Choose “EXCHANGE BATTERY?” and 
then press the [ENT] key. The display 
shows the following message. 
ARE YOU SURE?
YES
   
    
NO   
EXCHANGE
BATTERY?
 
Exchange battery prompt 
4. Press ◄ to choose YES and then press 
the [ENT] key. The following display 
appears. 
READY FOR
BATTERY CHANGE.
PRESS ANY KEY
     TO SHUT DOWN.
 
Battery exchange 
confirmation window 
5.  Press any key to automatically turn off the 
unit. 
6.  Replace the battery. 
 
Note 1:
 When it is expected that the 
equipment will not be used for a long time, 
execute the above procedure before turning 
the power off, to prevent loss of data. 
Note 2: Data is copied from the flash memory 
to the RAM at the next power up.