Nilfisk-Advance America SR 5110 P/B Manuel D’Utilisation

Page de 30
 
S31NUK5120(3)2001-04
 
PRELIMINARY OPERATIONS
 
2
 
- If the batteries are installed but not filled with 
acid solution they must be filled with a solution 
of sulphuric acid (density between 1,270 Kg 
and 1,290 Kg at 25°C temperature) according 
to the instructions specified below and in the 
Battery User Manual.
 
BATTERY FILLING UP WITH ACID SOLUTION
Warning: the battery acid is corrosive; if it 
comes in contact with the skin or eyes rinse 
thoroughly with water and consult a 
physician.
The batteries must be filled in a well 
ventilated area.
 
Fill every battery cell with acid; the right level is 
specified in the Battery User Manual. 
After one hour fill up with acid, if necessary.
Let batteries rest for a further hour; then proceed 
with a recharge according to the instructions 
specified in the Battery User Manual and in the 
MAINTENANCE paragraph. During the recharge 
the battery caps must be open.
 
WARNING: before starting the recharge the 
battery connector must be disconnected 
from the machine.
 
After the recharge close all the cell caps and 
clean the top of the battery from any acid 
remains.
 
6