Lucent Technologies 6.1 Manuel D’Utilisation

Page de 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Lines/Trunks 
Page 3-33
Selecting Line/Trunk Options 
3
9.
If assigning backup synchronization:
a.
In the box that describes the 100D module providing secondary 
synchronization, check Secondary.
b.
In the box that describes the 100D module providing tertiary back 
up, check Tertiary.
10.
Under the Source subheading in each box, do 
one of the following:
To retain the factory setting (that is, the system uses the clock of the 
far-end connection), check Loop.
To change the setting (the clock is free-running), check Local.
11.
The typical setup for the primary synchronization source is Active, and 
other modules are set to Not Active. Under the Activation subheading in 
each box, do 
one of the following:
If loop clock synchronization is taking place, check Active (factory 
setting).
If the clock is free-running, check Not Active.
12.
Under the Channel Service Unit heading, check Foreign Exchange.
PRI Options
3
If the switch is part of a private network, the PRI options are automatically set. If 
the switch is not part of a private network, after you have completed the module 
information on pages 1 and 2 of Form 3b, Incoming Trunks: DS1 Connectivity 
(100D Module), use the instructions in this section to record these PRI options:
Assigning B-channels to groups
Associating outgoing and incoming services to the groups
For groups with incoming services, selecting an incoming routing method 
(Dial Plan Routing or Line Appearance) and providing routing information 
For groups with outgoing services, completing the Network Selection, 
Special Services, and Call-by-Call Service tables
Identifying the trunk and telephone numbers sent to the network for caller 
identification
Assigning a test number used for maintenance by the service provider, 
changing timers and counters from the factory settings, and assigning the 
Terminal Equipment Identifier (TEI)
All channels assigned to a group must be on the same 100D module. Also, the 
order of the B-channel groups is not important. When programmed for PRI, the 
single DS1 jack on the 100D module supports 23 B-channels (the Channel 24 
superframe transmits signaling mode information).
!
CAUTION:
!
CAUTION:
The order in which channels are assigned within a group must be the exact 
opposite of the order in which the telephone company’s switch hunts 
through for a channel. Consult with the service provider to determine what 
the correct order should be.