Lucent Technologies 6.1 Manuel D’Utilisation

Page de 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Lines/Trunks 
Page 3-43
Selecting Line/Trunk Options 
3
Planning Form Instructions
3
1.
On Form 3d, under the Type heading, do 
one of the following:
To keep the factory setting, check the Wink-Start box.
To change the type, check the Immediate-Start box.
2.
Under the Expected Digits heading on Form 3d, do 
one of the following:
To show that the telephone company sends the factory-set number 
of digits, check the box labeled 3.
To show the number of digits sent by the telephone company, check 
one of the boxes labeled 1, 2, or 4.
3.
Compare the number of digits sent by the local telephone company to the 
number of digits in the system numbering plan, and do 
one of the following:
If the system’s numbering plan matches the number of digits sent by 
the telephone company, check 0 (the factory setting) under the 
Delete Digits and Add Digits headings.
If the number of digits sent by the local telephone company is 
more 
than the number of digits in the system numbering plan, specify that 
one to four digits be deleted from the telephone company digits by 
checking the appropriate number (1, 2, 3, or 4) under the Delete 
Digits heading.
If the number of digits sent by the local telephone company is 
fewer 
than the number of digits in the system’s numbering plan, specify 
the specific digits (1
9999) to be added to the digits sent; check the 
Add these digits box under the Add Digits heading and then write 
the specific digits to be added in the space provided.
4.
Under the Signaling heading, do 
one of the following:
To keep the factory-set signal, check Rotary.
To change the setting, check Touch-Tone. (You cannot have 
touch-tone if you selected Immediate-Start.)
5.
Under the Invalid Destination heading, do 
one of the following. (The Invalid 
Destination setting applies to both blocks. You cannot specify a different 
setting for each block.)
To indicate that calls to unassigned extension numbers go to the 
backup position (usually the primary operator), check Send to 
backup position.
To indicate that calls to unassigned extension numbers should 
receive a fast busy signal, check Return to fast busy.
6.
Group DID trunks into each block by assigning the DID trunks according to 
how incoming calls must be routed to reach the proper local and non-local 
extension numbers, and transfer the information from Form 2c, System 
Numbering: Line/Trunk Jacks to the Trunks Included in Block section of 
Form 3d. Write the logical ID, trunk number, and telephone number in the 
applicable columns.