Page 5-22
Assigning Extension Jacks 
5
Guidelines for Digital Extension Jacks
5
Although only one logical ID is assigned to each digital extension jack, the system 
automatically assigns two extension numbers:
The first extension number shown on Form 2a is assigned to an MLX 
telephone connected to the extension jack.
The second extension number assigned to each jack is reserved for an 
adjunct, such as an ISDN terminal adapter data terminal or desktop video 
endpoint, connected to the MLX telephone.
If a personal or group video system is connected to the MLX port, 
extension numbers are assigned to the video system for use in 2B Data 
connections.
Both extension numbers are assigned automatically, whether or not the extension 
includes an ISDN terminal adapter. Calls can be placed to both extension 
numbers independently. Note that an MLX extension cannot have both an ISDN 
terminal adapter and an MFM.
Also, when configuring digital data equipment connections to an MLX port, the 
following requirements and/or restrictions must be applied:
If using a 7500B data module as an ISDN terminal adapter, and it is the 
only ISDN terminal adapter data station on the MLX port (no MLX 
telephone is connected), a 440A4 terminating resistor adapter must be 
configured to provide 100-ohm termination for each transmission pair. The 
7500B data module does not provide termination.
An MLX telephone is independent from the ISDN terminal adapter; 
however, the telephone may cause channel conflict between the telephone 
and the ISDN terminal adapter when the telephone is voice-signaled while 
active on a call. If a slight chance of data call blocking is unacceptable, an 
MLX telephone should not be connected to an ISDN terminal adapter used 
in a data station configuration.
The maximum cord length from an MLX telephone to an ISDN terminal 
adapter is 80 feet (24 meters). This should be considered if you plan to use 
the voice capability of a port by connecting an MLX telephone far from the 
ISDN terminal adapter.
Do not connect an ISDN terminal adapter that does not support 2B Data to 
an MLX port that has been programmed as a 2B Data port.
When using the 008 MLX or 408 GS/LS-MLX module for data or video, you 
must use Version 28 of the module.